AC leaking at light fixture.

jayc

Texas-South Chapter Leaders
Sounds like one of the a/c ducts has fallen down and pumping air through the light. Contact you dealer to have it checked.
 

Garbo47

Member
Thanks. I do notice the air does not seen to blow out hard in the ducts when I have the dump feature closed on the ac.
 
Ducts disconnect from time to time. Hopefully someone can get to the duct easily and reconnect it. Is there access above the vent? I contacted a indianapolis air conditioning company when I needed help. They were able to help me figure out how to access it.
 
Last edited:

hoefler

Well-known member
Start at the A/C. Pull the grill down and make sure there is no holes between the duct and the A/C plenum. This is where I found an opening about 3/4" x 4", where it was blowing cold air into the ceiling. Next start taking down each register and make sure there is no gap between the duct and the ceiling. The ducts are only taped in with foil tape at all the outlets.
 