ER 27RLSS with no water pressure from 12v water pump

chrisr

Member
I have a 2011 ER 27RLSS I bought new a year ago. We have never had an opportunuity to use the 12v water pump until recently. City water works fine. Needless to say, when I tried the onboard water pump, the pump was running but there was no water running. My first step is to check the connections on the pump. Where is the pump?
 

danemayer

Well-known member
Hi chrisr,

The water pump is usually behind the UDC where the city water hooks up. On many rigs, you have to take down the basement wall that's behind the UDC.

Before you do, take a look at the winterizing levers. Maybe you're pulling air through the antifreeze tube.
 

olcoon

Well-known member
chrisr
We also own a 27RLSS, so maybe I can help you. The water pump is behind the UDC, and you can access it from that side of your coach. There is a 2x2' panel located near the top of the rear bulkhead, but I would unscrew the 2 screws in the top & bottom of the bulkhead itself & slide it out. You'll have to be careful, as there is a duct hose coming from the furnace that goes behind the bulkhead to heat the area back there. Just work it through the hole as you slide the bulkhead out. You'll be able to see & reach the water pump then. There are some of white hoses down there, one of them is the suction line that is used to winterize the coach, it would go into the jug of anti-freeze, it's not connected to anything. It has a valve on it, and near it, close to the water pump is another white hose with a valve on it. I'm thinking that these valves were left in their winterizing position. Just change the position of the valves, & hopefully the pump will start working. Hope this helps. Right now we are in Donna, TX & will be leaving Monday for the Sweetheart Rally in Kerrville. Not sure where we'll be after that. I see that you are near Houston, if you happen to be in either area while we are there I'd be happy to help if you need it, & show you some mods we've done to ours. Just PM me & I'll give you my cell, if you are interested.
 

chrisr

Member
Hey Guys,
I got to look into my water pump issue today. I found two issues. First, I was having problems filling the fresh water tank. The gravity hose on the back of the UDC was approximately 6" too long forming a trap behind the fill connection. I removed approximately 6" of the hose, rerouting the hose over the bundle of hoses creating a straight gravity feed. Works great now. The pressure issue was the winterization valve was open. I now have water pressure from the pump. Thanks for the info......
 