Voltage to pump

kickinbar

Member
Hi... New Cyclone (used) owner and first time forum poster.. just bought a 2007 Cyclone 3210..one owner excellent condition.. Except for a water pump issue. I am getting only 6 volts to the pump..which obviously isn't enough for it to run.. I did hook the pump directly up to a 12 volt source and it works fine. I do get 12 volts to the outside switch but the blue wire that goes to the pump only shows 6 volts.. Anyone have any ideas... Great forum..love reading the posts!!
 

cookie

Administrator
Staff member
Have you checked the fuses? When a fuse is blown there is still some low voltage that goes to the device. The red LED in the fuse panel will only light up if the device is calling for 12 volts, so the pump switch must be turned on for the LED to glow.

Peace
Dave
 

kickinbar

Member
Dave thanks for the quick response. I just went back out to the check the fuse and that was it..was wondering what the leds were for!!! Works great now....thanks again....
 
Top