  1. B

    New RW 427 generator starving.

    It was the fuel pump. Replaced the Onan fuel pump with an Airtex. Tested for an hour today successfully. Only got about 20 hours out of the original pump, hopefully this one last a long time. Thanks for the suggestions. Now on to other bugs like awning not fully retracting, leveling system...
  2. B

    New RW 427 generator starving.

    Good idea. Relocating the fuel pump did not help. The top of the tank is not accessable without dropping it. I'll leave the gas cap off and try it again before installing a new fuel pump. I tested the fuel pump on my bench and it pumped but I didn't think to put a pressure gage on it. If it...
  3. B

    New RW 427 generator starving.

    2016 RW 427 with RT package. Generator ran fine for first 20 hours or so. Gen died from gas starvation. Changed the filter on the fuel pump under the Onan thinking there might be trash in the new fuel tanks. Ran for about 10 minutes and starved out again. Changed filter again and pump would...