Search results

  1. StephenW

    RESOLVED - 2019 Cyclone no heat/too much heat

    Re: 2019 Cyclone no heat/too much heat Yes it is. I verified on/off cycle from bedroom tsat.
  2. StephenW

    RESOLVED - 2019 Cyclone no heat/too much heat

    Re: 2019 Cyclone no heat/too much heat Dan, Thank you for the help. The 2 female spade terminals for the tstat loop had stray wires when they were crimped and acting like a jumper. Cleaned the wires up and turned both terminals opposing each other.
  3. StephenW

    RESOLVED - 2019 Cyclone no heat/too much heat

    Re: 2019 Cyclone no heat/too much heat It has been like this each time I apply power. This past weekend was my first trip out since purchasing the unit. I can hear a contact close in the main bedroom A/C unit as soon as I apply power to the RV.
  4. StephenW

    RESOLVED - 2019 Cyclone no heat/too much heat

    I have a 2019 Cyclone 4007 with furnace issues. I understand that the bedroom t-stat operates the furnace. My heat is either wide open or not present. Below I will describe scenarios. 1. Apply shore power and furnace tries to ignite 3 times before faulting out. None of the t-stats are on and...