  1. H

    grey tank empty

    You have cable operated valves, the cables have failed and won't close the valve completly. I wen to Barkley electric operated valves and haven't had any more issues since. Going on 10+ years.
  2. H

    grey tank empty

    you have a blockage somewhere in the system
  3. H

    Converter humming

    Yes normal. Since you boondock, the convertor is working double time charging the batteries.
  4. H

    Putting new batteries in Fuel 305, got a little arc, now there is clicking near duel batteries on front of trailer?

    Reverse polarity Black is positive , White is negative. The breaker is protecting your convertor.
  5. H

    My Torque 371 has been wearing tires bad

    What are you hauling in the garage? A 1500 pound side by side in the garage will actually load the axles close to 3000 pounds. Think of your trailer as a teeter totter, the axles are the fulcrum, as you load one end, the other rises. Thinking of theis, you will transfere weight from the front...
  6. H

    Receptacle Issue

    Check the breakers on the generator, cycle them. Look for the 30amp or 50 amp transfer switch for the generator. See if it is getting power from the generator.
  7. H

    2017 Heartland Sundance XLT 283RB pump

    24 gallons isn't very much very water after filling the water heater and lines, you may just be sucking air from the water tank being low. The angle of the trailer has an affect on the outlet of the tank, the angle of the tank mounting will also have an affect. One more thing, the outlet is...
  8. H

    Receptacle Issue

    The invertor and 15 amp transfer switch is for the residential fridge, only, and nothing to do with anything else. Are you using and onboard genderator or a stand alone? Either way, cycle the breaker on the generator.
  9. H

    is it possible to heat bedroom area of 5th wheel trailer only to save on battery life

    Closing off vents will cause the furnace to overheat and shut down, possibly requiring a manual reset, depending on model and age of the unit. They are designed to have X amount of air moving across the heat exchanger to prevent melt down or fire.
  10. H

    Truck trying to do a re-gen

    Excessive idling will cause an idle up to heat up the exhaust or to keep it hot, it is not for regeneration. The light duty pickups do not use the same programing as class 7 & 8 over the road trucks. Light duty pick ups will never do a stationary regeneration, unless forced by a technician.
  11. H

    2014 Heartland bighorn 36tb

    Remove the blower assembly, check for a wasp nest preventing the blower to spin. While you're in then, inspect the heat exchanger for any obstructions, such as wasp nests.
  12. H

    Black Tank Flush

    They also freeze if not winterized
  13. H

    Black tank dump valve access 2007 Big Horn 3055RL

    If your 07 is similar to my 06, your black tank valve is connected by a rod from the UDC, not a cable like on the grey tanks. Pumping out through the toilet may not be an option due to how the plumbing is routed. Take the belly skin down at the edges and look for the tank locaion, probably...
  14. H

    Landmark Battery Problems

    Open/out of limits or no tone means no connection between test points. Sound like you have a burnt or loose connection internally.
  15. H

    Hydraulics for 3300dl

    Are you checking it with the slides out and jacks extended? You need to check the level with everything retracted.
  16. H

    Landmark Battery Problems

    Using a multi-meter, you test for continuity and resistance on the black lead
  17. H

    Landmark Battery Problems

    You mentioned you are using a 30 amp outlet. Your rig is a 50 amp unit. When you are using an adaptor to convert 30 to 50 amp, you tie both hot legs together. The adaptor could be bad and not suppling power to both legs equally, probably the leg that the convertor is on.
  18. H

    Lippert Leveling system not working

    Have the battery/batteris tested first!
  19. H

    Batteries in winter

    If you can plug the trailer in, leave the batteries in the trailer, your convertor will maintain the batteries
  20. H

    2021 21RBSS - Bulge in the flooring of the storage

    Floor screw backed out. Slice the vinyl enough to screw it back down, then use vinyl seam , or clear PVC glue, to repair where you cut it.
  21. H

    Dometic Blizzard AC Replacement

    You have to replace the communication cable to the thermostate. if you are using one thermostat to run both units, you have to set the dip switches to designate zone 1 and zone 2.
  22. H

    Refrigerator not cooling T333

    How long has it been on? Did you let it cool down before loading it?
  23. H

    Kitchen Sink

    Try sanitizing your fresh water system. Since it only smells when running the water, you may have a bacteria growing in that section of water line.
  24. H

    Slide topper billowing

    Needs to be rotated closer to the contact plate the wall. Take the arm loose, barely extend the sliderotate the arm to see if it clears the wall, should clear by about a 1/4".secure it at it's closest point to the wall. then bring in the slide. It will be closer to the conttact point on the...
  25. H

    Getting a new sofa through the doors

    We had to stand the couch on end and rotate/spin it through the door.
  26. H

    Mallard TT Shower Doors won't stay in tracks

    Do you lock them in place for transit?? You need to have them locked so the don't move while going down the road.
  27. H

    Slide topper billowing

    Relocate the anti-billowing arm closer to the stop
  28. H

    Lippert leveling system "out of stroke" error

    Manually retract all jacks, this should reset the system to zero.
  29. H

    Dometic Blizzard AC Replacement

    What part of Missouri are you in?? I work on RVs, house boats, Etc. Im on the west side of Table Rock Lake
  30. H

    Brake voltage

    Since everything is new, consistant results cannot be expected until the brake shoes, drums, magnets, etc.. are burnished in. This will take anywhere from 500 to 1500 miles depnding on driving conditions that require braking. Will also require adjusting several times to get even braking. The...
  31. H

    2017 North Trail 22RBK Water Pump issue

    Make sure your anderson valve is on tank, check the strainer and make sure it isn't cracked
  32. H

    Dometic Blizzard AC Replacement

    You must have 12 volt at the red and black wires, it won't operate with out 12 volts on these 2 wires. Do not try to supply 12 volts directly to the thermostat! It's supply comes through the communitaction cable
  33. H

    Dometic Blizzard AC Replacement

    Make sure yiou have 12voltg at the yellow/white wires and you also have a good ground. The thermostate and a/c is controlled by 12 volt power.
  34. H

    Dometic Blizzard AC Replacement

    There are 2 couplers that look like phone jacks that go to your thermostat, swap them. There should be 12 volt power at both of these, I just installed 2 NXTs 2 weeks ago. I after much back and forth, I learned they are both to have power. I had to open up the control box and found that one...
  35. H

    Swivel wheel trailer on 14 landmark san antonio

    It's what you don't see, when the rig swings into another vehicle or object.
  36. H

    Outlets

    Start with the outlet your rig is plugged into. Has this outlet been used before or is it a recent addition? Your rig 50 amp or 30 amp?
  37. H

    My kitchen sink fills with dirty water

    I would get all 3 valves open first of all. Then verify wich one goes to which tank.
  38. H

    Swivel wheel trailer on 14 landmark san antonio

    Just think about your tail swing, it will increase significantly. When I had my swivel wheel, I would see it going into the other lane when turning at intersections.
  39. H

    Broken Spring Hanger.....Again. and what to do about my tires too close together

    This is caused by the hangers flexing will turning the trailer, the supports that were added did nothing to help the hangers flexing, actually made it worse. By stopping or limiting the flex in the frame, all the stress is on the hangers. The hangers need to be gusseted or supported to stop...
  40. H

    Shower and sink

    Check for a diverter on the faucet. Picture of it would help