The winterize position will pull water from the fresh water connection by the pump. So, yes you will still get water at the faucets. This position is designed to pull antifreeze from a bottle using a hose.
It will fill the fresh tank from this position if the backflow preventer is bad in the...
I was also told by Heartland cutting a hole in the framing stud would have no adverse affects. I did drill test holes before making my hole to verify no studs were in the way.
I'm thinking that since you don't have jacks in the middle the suspension is giving when the slides go out causes the un-level condition. You could get some screw type jacks to go in the middle to add support. The only way I know to level from side to side is with blocks under the tires.
Bungy cord for me wrapped between handles with small pieces of swim noodles over each door handle in case the doors bounce open when traveling. Keeps the door handles from hitting the island.
What is the make and part number of the rear stabilizer you used. I want to do the same thing. My DW wanted me to add permanent rear jacks. I like your solution better.
I will second that on staying away from Samsung. Tech told me they have the most failures of any brand. His recommendation is Frigidaire/Electrolux. Also, Samsung has a standing recall on their icemaker In most models that have the icemaker in the top left of the double door model. That being...
From Google:
A truck averaging 6 MPG can expect to go approximately 300 miles on one gallon of DEF. Q. How can an operator determine how much DEF they will need/use? A. DEF consumption will be approximately 2% of the diesel fuel consumed. Another way to consider it is that DEF will be consumed...
If your TV has an HDMI with a Audio Return Channel (ARC) then purchase a sound bar with the same capability. That way the TV and sound bar can talk to each other and you will only need one remote. Plus when you go to your audio options on the TV to choose the output source the sound bar will be...
Just my thoughts, it might cost less to replace the existing awning with an electric one so the DW can extend and retract at will versus repairing the fifth wheel after a wind gust rips the awning off the trailer. Seen it many, many times with awnings that were tied down. Get up in the AM to...
Same here, no issues in almost 2.5 years, with the exception of me forgetting to winterize it and freezing the whole trailer. I hope I am not jinxing myself but really absolutely no issues with the trailer itself. Had to change out the door control panel on the refrigerator last trip but that...
I could not get the nuts loose through the hole in the shower. I have a front bath in mine. I had to remove the door to the bathroom, remove the door frame attached to the wall. Its only held with 3 staples and the screws that hold the door hinges. Then I was able to carefully pull the wall...
MCTalley, when you changed your upstairs toilet in your old 3950, do you remember the hole to wall spacing? I ask because the Dometic 310 has a 10 inch spacing instead of the 11.5 like the 320.
There are other choices besides the 320 that may have the desired wall to hole spacing you need. What about the Aqua-Magic Residence RV Toilet, it has the 9.5 inch wall spacing and it comes in high profile or you really want to feel like a king check this one out, Thetford 38264 RV Toilet. Most...
I use Direct TV because that is what I have at home. I take the receivers with me when I travel. I use this http://www.tv4rv.com/sunshop/index.php?l=product_detail&p=13
with a Dish I bought from the same company http://www.tv4rv.com/sunshop/index.php?l=product_detail&p=104. Easy to set up and...
The MUO-016 is for non-Correct Track springs which Amazon carries. Amazon does not carry the MUO-029. But I was able to find it from RV & Auto Parts for $109.04. Glad I posted here because I would have ordered the MUO-016 from Amazon. I had already put it in the Cart! Once Gary521 mentioned...
Do you know the difference between the two, with correct track and without? I have correct track with the yellow shim on the leaf spring.
Looks like the Correct Track part number is UO12-029
Non-Correct Track is UO12-016
Both of these part numbers will work with either the CRE-3000 or SRE-4000
Thanks for the info. Do you have the part numbers for the wet bolt kit and shackles that will fit the SRE4000? I want to make sure I order the correct part numbers.
My buddy who owns a SOB found one of the shackle bolts completely missing. He doesn't know how long it was missing but says he has...
I know some of you have done this upgrade an now I am ready but I can't seem to find a common part number for the MORryde shackles to be used with the SRE4000 system. Amazon has a couple of different part numbers which is the correct one. The UO12-016 is shown with the SRE4000 but is listed for...
What model Big Country do you have. I froze mine two weeks ago and am happy to say the Pex lines are pretty tough against freeze. But everything else, not so much. We froze the shower fixture, toilet water valve and water pump backflow preventer. Crazy thing is, each one leaked separately. In...
Re: Frigidaire Error Code (solved)
Received both boards and replaced the board in the door. Frigidaire said the board in the door is the most probable. Using a flat plastic tool, pry the edge panel away from door. It is held in place by small spring clips. Disconnect two connectors and the...
Sorry to hear of your troubles. I went through the same thing with the Explore USA in Fort Worth. I wrote a long post here on this forum and 2 days later got a call for the manager of Explore USA wanting me to explain my post about his store. He did not deny anything I said but promised to make...
Discount will replace/repair any tire they sell. They will not repair the damage caused by a blowout from one of their tires. Also, I have checked 3 different Discount Tire stores and not one store could air a tire past 90 psi. Be aware if you purchase 110 psi tires from Discount they may have...
Re: Leak in shower 3950 FB
I found the leak by pulling the walls, cheap Dura faucet failed right where the main water line connects to it will replace it tomorrow.
In the front bathroom of my 3950 FB whenever the shower runs water comes from underneath the shower tub and also gets the carpet in the bedroom wet right next to the wall opposite the shower. I removed the access panel while water was turned on and everything is dry in there but I can't see all...
After you make your hole but before you place the dryer, attach the hose to the dryer, push the hose though the wall then position the dryer in place. Then go outside and attach the vent after trimming the hose to length. This is way easier than trying to connect the vent hose after the dryer is...
This is what I mounted under my sink. Pressure Tank on the right and filter system mounted on the left side. Still have room for cleaning supplies ect. Filters last anywhere from 6 months to 1 year. Replacement set of filters is $70.00. Filters down to 20 ppm. Bottle water is around 12 ppm...
Re: Frigidaire Error Code
This is an error between the power control board located behind the front kick plate and the door controls. Power control board and control board in door should be changed at the same time to prevent communication issues between an older board and a new board. To...
I awoke this morning with an error code of SY CE - "Communications error at power up" on my Frigidaire. Searched the internet and it said to cycle power but this will clear the fault code. Well had to get the it working so I went outside and cycled power at the pedestal and noticed a previous...
Is there anything wrong with sealing this vent in the summer? I feel a lot of warm air coming in from the vent when the A/C is running. I know it has to be open in the summer
That's what we did, now I need to change the one in the house. I keep forgetting and let the lid slam down. Scares the you know what out of you if you do it a night.
I like that, I was scrambling to find a fitting I could screw into the line to be able to still have water and use the upstairs toilet. I think I will go to lowes and investigate fittings. Mine comes out of the wall should be able to do the same. Thanks for the idea!
Changed the water valve last night, piece of cake. Just pressed on the top catch and the valve popped right out, didn't need to pressed on the bottom catch. Removed the clamp on the line that goes to the top of the toilet and reattached to the new valve with the provided hose clamp and slid the...
Thanks Dan for you advice. My understanding of the water valve is it has a freeze plug of sorts that is designed to blow out first. Funny thing is I always turn on the pump first to check for leaks or loose connections and the pump pressurized just fine. I turned off the pump and put city water...
Sorry to hear about the damage to your home. Try to find an independent repair center that is sympathetic to the fact that this is your home. I dropped mine to be repaired and it took months. Thankfully I don't live in it full time. Between scheduling the repair and ordering and receiving parts...
Does anyone know if the water inlet valve can be changed without pulling the toilet. I get to change one when I get home from work tonight. Anyone have a guess why I get to change one??? Stupid me, 35 years of owning RVs and this is the first time I forgot to flush the toilet to get antifreeze...
When I had my front cap replaced late last year the repair facility said that it appeared the front cap had been leaking water for a long time. Everything was rusty and the little bit of insulation inside had shown that it had been wet in the past. Fortunately there is a vapor barrier in there...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.